Surgery > QUESTIONS & ANSWERS > C.S. Certification Exam, SPD Test, Sterile Processing Study Material for Certification Exam Latest 2 (All)

C.S. Certification Exam, SPD Test, Sterile Processing Study Material for Certification Exam Latest 2022 Already Passed

Document Content and Description Below

C.S. Certification Exam, SPD Test, Sterile Processing Study Material for Certification Exam Latest 2022 Already Passed Which area is the first to accept responsibility for all supplies in the faci... lity? ✔✔Receiving Which type of inventory distribution system requires the use of a pre-determined inventory list? ✔✔Par Level Just-in-time distribution systems are also known as ✔✔Stockless Distribution Ordering the optimum quantity of an item based on historical data is known as ✔✔Economical Order Quantity Which of the following are elements of a distribution system? ✔✔patient charging, storage, and receiving The most efficient distribution system is the ✔✔Total exchange cart The computerized locked supply system is a variation of the ✔✔Par Level Which distribution system requires the using department to be responsible for maintaing inventory levels? ✔✔Demand An ongoing inventory management system is known as a ✔✔Perpetual Inventory System In which distribution system are requisition filled and delivered as they are received? ✔✔DemandInventory performance" (a rough indication of the effectiveness of the inventory system) is evaluated by ✔✔percent of back order, availability of critical items, and inventory turnover Which of the following is the MOST efficient and cost-effective method for inventory control in the SPD ordering and data generation? ✔✔Computerized Inventory Control System The temperature in the sterile storage are should not exceed ✔✔75º F (24º C) Shelving in the sterile storage area must be kept how far from the outside walls? ✔✔2 inches The thickness of a sterility maintenance cover should be ✔✔2 to 3 mils The minimum number of air exchanges per hour in the sterile storage area should be ✔✔4 The relative humidity in the sterile storage area should not exceed ✔✔70% Approximately how much space should be left between and item and the inside edges of a peel pouch? ✔✔1 inch What is the maximum size and weight of a textile pack? ✔✔12" x 12 x 20" 12 pounds Which of the following packaging materials is acceptable for low-temperature gas plasma and ozone sterilization ✔✔Tyvek Basin sets should be prepared for sterilization with ✔✔an absorbent material between each basin Tamper-evident seal on rigid containers include ✔✔latches and locksWhat is the acceptable temperature range for the prep and packaging area? ✔✔68º F-73º F (20º- 23º C) The preparation and packaging area must have an air exchange rate of ✔✔10 per hr If a non-perforated tray is used for the sterilization of instrument sets, it must be ✔✔Tilted on the sterilizer rack The ideal humidity level in the preparation and packing area should be ✔✔50% For sterilization, rigid containers must be placed ✔✔flat Which of the following packaging materials is acceptable for steam sterilization? ✔✔Non-woven wraps Re-passivation of an instrument can be achieved by ✔✔routine lubrication What is the most difficult part of a hemostat to clean? ✔✔box lock Which of the following lubricants is recommended for use on surgical instruments? ✔✔petroleumbased What type of finish on a surgical instrument is used for laser procedures? ✔✔ebonized What is the final stage in manufacturing a surgical grade instrument? ✔✔passivation Which series of stainless steel is used is to manufacture malleable retractors? ✔✔300 The weakest part of the instrument is/are the ✔✔box locksThe layer on a surgical instrument created by the passivation process is called ✔✔chromium oxide A crack in a hand-held instrument would most likely be found in the ✔✔box lock The appropriate sterilization cycle for an autoclave load containing a basin set, a minor surgery set, and twelve towel packs is ✔✔270 F (132 C ) for 4 minutes, 30 psi and 20 minutes drying time Cotton gauze cannot be used in which sterilization process? ✔✔low temperature gas plasma Which agencies are involved with the regulation and control of ethylene oxide when it's used as a sterilant? ✔✔environmental protection agency, food and drug administration, and centers for disease control and prevention Which of the following sterilization methods would be appropriate for petrolatum gauze dressings? ✔✔dry heat To eliminate the bioburden on metal surgical instrument within the SPD, the MOST cost-efficient sterilization method is generally considered to be ✔✔steam under pressure There are two pressure gauges on a steam sterilizer. These gauges measure the pressure in the ✔✔jacket and chamber What is the maximum number of 100% EO cartridges permitted by OSHA to be stored outside of a flammable goods cabinet? ✔✔10 At the end of the sterilization cycle, the EO cartridges and the gloves used to handle them should be ✔✔AeratedItem to be sterilized in low-temperature gas plasma must be packaged in: ✔✔Non-cellulose-based material Generally, the EO biological test pack is placed in the ✔✔Geometric center of the load Which of the following devices are compatible with ozone sterilization? ✔✔stainless steel instruments Routine BI testing for steam sterilizers should be performed at least ✔✔weekly The parameters for low-temperature gas plasma sterilization are: ✔✔Time, temperature, hydrogen peroxide gas plasma Which of the following can be processed in a low-temperature gas plasma sterilizer? ✔✔light cords, cameras, and single channel endoscopes The Action Levels for EO expoure is ✔✔0.5 ppm Which of the following is critical to EO penetration of bacterial cells? ✔✔humidity The packaging of choice for dry heat sterilization is: ✔✔aluminum foil The basic parameters of gas sterilization in a 100% EO sterilizer are concentration, exposure time, ✔✔humidity and temperature Which of the following microorganisms is used to biologically monitor the dry heat sterilizer? ✔✔Bacillus atrophaeusIf a biological test is performed daily, how often is it necessary to incubate a control biological indicator? ✔✔once a day, and if a new lot number is used Which of the following microorganisms is used to biologically monitor the low-temperature gas plasma sterilizer? ✔✔Geobacillus stearothermophilus Which of the following microorganisms is used to biologically monitor the ozone sterilizer? ✔✔Geobacillus stearothermophilus Which of the following is the correct sterilizer setting for the Bowie Dick test? ✔✔3 to 4 minutes at 270º F (132º C ) pre-vac What are the minimum air exchanges to be maintained in a area where 100% EO cartridges or EO mixture cylinders are stored? ✔✔10 per hour Which of the following packaging materials are recommended for EO sterilization? ✔✔Polypropylene, Paper-plastic pouches, Tyvek Which type of microorganism has the ability to slow down its metabolism and become dormant? ✔✔Gram-positive bacillus The shape of a spirochete is ✔✔spiral Which of the following is true of fungi? ✔✔They include single celled yeasts Protozoa are ✔✔single-celled microorganisms Which of the following is true of fungi? ✔✔Staphylococcus aureus is a ✔✔gram positive coccus Bacilli are ✔✔rod-shaped The shape of the Strepococcus is ✔✔spherical What is the shape of cocci? ✔✔round Vancomycin-Resistant Enterococcus (VRE) can survive on the hands for ✔✔hours Bloodborne pathogen exposure is regulated by ✔✔OSHA Healthcare-acquired infections account for more than ✔✔90,000 deaths annually The general term for any inanimate object involved in the spread of infection is ✔✔fomite An infection caused by a needlestick enters through which portal of entry? ✔✔parenteral tissue Which method of sterilization is used to sterilize liquids? ✔✔gravity steam Which of the following is the minimum exposure time for wrapped goods in a pre-vacuum steam cycle at 275º F (135º C)? ✔✔3 minutes Which of the following is the recommended cycle for processing decontaminated instruments from a suspected CJD case? ✔✔18 minutes, 273º F (134º C), prevac cycle The three parameters of steam sterilization are ✔✔steam under pressure, time, and temperature The sterilizer's heat-sensing thermometer is located in the ✔✔drain lineA solution having a pH of 9 is ✔✔Alkaline Which of the following government agencies regulates environmental disinfectants? ✔✔EPA Medical grade Kraft paper cannot be used with which of the following sterilization processes ✔✔Low temperature gas plasma During cycle counts items that have a large dollar value but are not used frequently are classified as ✔✔A Anatomy is the science that deals with the blank of body parts ✔✔Structure Which of the following transports molecules into the cell ✔✔Cytoplasm Why is it important to evenly distribute large instruments in a set ✔✔Extra condensation will make the set more difficult to dry Which of the following best describes the overall role of the Cs / SPD ✔✔To provide Dependable service to enhance patient care Which of the following organs produce bile ✔✔Liver Microorganisms are measured in ✔✔Microns With respect to rigid sterilization containers testing which term defines the sterilizer ability to sterilize under actual use condition ✔✔Maximum loading testing What is the ideal human body temperature ✔✔98.6 degrees FahrenheitWhat may be the cause of a blue stain on a scope in Ortho phthalate Hyde ✔✔Improper cleaning Which of the following is true of a capsule ✔✔It is resistant to heat and chemicals Which of the following is necessary to obtain the high temperature needed in a steam sterilizer ✔✔Pressure Ethics is the practice of ✔✔Doing the right thing A microorganism that is resting and has a hard shell like outer covering is called a ✔✔Spore Nails tissues and money are examples of ✔✔Fomites Cholera is transmitted by ✔✔Vehicle In the final step of hand-washing the fingers should be rinsed with the fingertips ✔✔Up Waterless hand antiseptic contains what percentage concentration of alcohol to make them most effective ✔✔60% to 95% All of the following play a role in how bones support other body systems except ✔✔Distribution of hormones OSHA requires that containers of potentially infectious material be ✔✔Leak proof Round or spherical bacteria are called ✔✔CocciThe removal of contamination from an item to the extent necessary of the future processing is called ✔✔Cleaning Ventilation in the decontamination area should be ✔✔Negative pressure with 10 air exchanges per hour Which of the following should be cleaned daily ✔✔Floors & work surfaces Which of the following is true statement regarding the use of PPE in the decontamination area ✔✔Failure to wear PPE can result in disciplinary action Before a medical device is cleaned and processed ✔✔The manufactory instructions must be obtained The minimum time needed for effective hand-washing ✔✔15 seconds Which of the following is not a consideration when selecting a detergent ✔✔Cost of detergent The relative acidity or alkalinity of a solution is referred to as its ✔✔PH What is the weakest part of an instrument ✔✔Box lock The solution having a pH of 13 is ✔✔Alkaline Which of the following are major nonliving reservoirs of infectious disease ✔✔Soil and water Alkaline detergents are best for mechanical washers because of ✔✔A lack of [Show More]

Last updated: 1 year ago

Preview 1 out of 41 pages

Add to cart

Instant download

document-preview

Buy this document to get the full access instantly

Instant Download Access after purchase

Add to cart

Instant download

Also available in bundle (1)

C.S. Certification Exam, SPD Test, Sterile Processing Bundle. Complete Questions with accurate answers,

C.S. Certification Exam, SPD Test, Sterile Processing Bundle. Complete Questions with accurate answers, All ypu need to score A

By bundleHub Solution guider 1 year ago

$45.5

32  

Reviews( 0 )

$7.00

Add to cart

Instant download

Can't find what you want? Try our AI powered Search

OR

REQUEST DOCUMENT
83
0

Document information


Connected school, study & course


About the document


Uploaded On

Sep 27, 2022

Number of pages

41

Written in

Seller


seller-icon
bundleHub Solution guider

Member since 2 years

313 Documents Sold


Additional information

This document has been written for:

Uploaded

Sep 27, 2022

Downloads

 0

Views

 83

Document Keyword Tags

More From bundleHub Solution guider

View all bundleHub Solution guider's documents »
What is Browsegrades

In Browsegrades, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter