Education > QUESTIONS and ANSWERS > EPA 608 (TYPE II) Exam Questions and Answers (All)
When a new system has been assembled, the first thing to do is? - Answer- Pressurize the system with an inert gas & leak check. After installation of a field-piped R-410A split heat pulp, the unit ... should first be? - Answer- Pressurized with nitrogen then leak checked. The EPA regulations require that any appliances containing more than 50 pounds of refrigerant (except for commercial & industrial process refrigeration) must be repaired when the leak rate exceeds _________ of the charge per year? - Answer- 15% R-410A requires recovery tanks rated for at least? - Answer- 400 psig After refrigerant liquid has been recovered from a system, any remaining vapor is? - Answer- Condensed by the recovery system. Your recovery/recycling machine has R-502 refrigerant in it. You now have to recover refrigerant from a unit with R-22. What must be done before the R-22 refrigerant can be recovered/recycled? - Answer- Recover as much R-502 from the recovery unit as possible, change filter, & evacuate. In a refrigeration system with a TXV (or other type of throttling device), the component directly following the condenser is the? - Answer- Receiver When charging an R-410A system that uses a water-cooled condenser, you must first charge with vapor to a pressure of at least________, before switching to liquid charging. - Answer- 120 psig Recovered refrigerant may contain what? - Answer- 1.) Acids 2.) Moisture 3.) Oils Your recovery/recycling machine has R-22 refrigerant in it. You now have to recover refrigerant from a unit with R-410A. What must be done before your recovery unit can be used to recover R-410A? - Answer- 1.) The recovery unit must be EPA certified for use with R-410A. 2.) The recovery tank must be designed for the pressure of R-410A. 3.) The filter & lubricant in the recovery unit must be changed, & the recovery unit evacuated. To recover liquid refrigerant, you must connect one hose to the? - Answer- Liquid Line. The proper charging method for blended (non-azeotropic) refrigerants (400 Series) is to use a remove the charge from the cylinder as a? - Answer- Liquid Before using a recovery unit to remove a charge, what steps should be taken? - Answer- 1.) Check service valve positions. 2.) Check the oil level in the recovery unit. 3.) Evacuate recovery unit & recovery tank. On refrigeration units that use an open compressor; the ________ is most likely to leak if the unit is not used for several months. - Answer- The rotating shaft seal. Noncondensables in a system cause? - Answer- Higher discharge pressure. Heat Pumps that use R-410A should be leak checked with? - Answer- Pressurized Nitrogen. A reciprocating compressor should not be energized when? - Answer- The discharge service valve is closed. In a refrigeration system, the component directly following the evaporator is the? - Answer- Accumulator. Manifold gauge set hoses should have self-sealing connectors or hand valves to? - Answer- Minimize the release of refrigerant when the hoses are connected & disconnected. The EPA regulations require that leaking commercial or industrial process refrigeration equipment must be repaired when the leak rate exceeds _____ of the charge per year. - Answer- 35% Moisture is removed from a system by? - Answer- Using a filter drier. Oil foaming usually occurs in the? - Answer- Compressor R-410A is different from other ASHRAE 400 series non-azeotropic blends because? - Answer- R-410A behaves as a near azeotropic refrigerant, & can be topped off. With an air-cooled condenser on the roof of a building & the evaporator on the first floor, recovery should first occur? - Answer- From the liquid line entering the evaporator. A deep vacuum is usually measured in? - Answer- Microns. Heat Pumps that use R-134A should be leak checked with? - Answer- Pressurized Nitrogen. During the evacuation of a system that contains large amounts of moisture it may be necessary to increase pressure in the system with ________, to counteract the freezing of the moisture. - Answer- Nitrogen. When under a deep vacuum, the motor winding of a hermetic refrigeration compressor? - Answer- Will be damaged if energized. When using recovery or recycling equipment that was manufactured AFTER November 15, 1993: you must evacuate a system containing MORE than 200 pounds of CFC-12 to _______ before making a major repair. - Answer- 15 inches Hg vacuum When inspecting a system for leaks, you should look for? - Answer- Traces of oil. Refrigerant leaves the receiver of a system as a? - Answer- High pressure liquid. A compressor heater is used to? - Answer- Reduce the amount of refrigerant in the lubricating oil. The evaporation temperature of R-134a at 0 psig is? - Answer- -15F Dry nitrogen should be used to break the first vacuum when dehydrating by the double evacuation method. However, it? - Answer- Can be dangerous if not used with a pressure regulator. When servicing a 60-ton packaged rooftop unit. The easiest way to check the type of refrigerant is uses is to? - Answer- Look at the unit nameplate. R-410A requires certified recovery & recycling machines rated for at least? - Answer- [Show More]
Last updated: 9 months ago
Preview 1 out of 6 pages
Connected school, study & course
About the document
Uploaded On
Jul 01, 2023
Number of pages
6
Written in
This document has been written for:
Uploaded
Jul 01, 2023
Downloads
0
Views
42
In Browsegrades, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.
We're available through e-mail, Twitter, Facebook, and live chat.
FAQ
Questions? Leave a message!
Copyright © Browsegrades · High quality services·