Environmental Science > QUESTIONS & ANSWERS > EPA 608 Practice Test #1, Questions and answers, 100% Accurate, rated A (All)

EPA 608 Practice Test #1, Questions and answers, 100% Accurate, rated A

Document Content and Description Below

EPA 608 Practice Test #1, Questions and answers, 100% Accurate, rated A What is a blend of two or more components who's equilibrium vapor phase & liquid phase compositions are the same at a given... pressure? - ✔✔-Azeotrope This is a halogenated hydrocarbon containing one or more of the three halogens: fluorine, chlorine, and bromine - ✔✔-Halocarbon Chlorofluorocarbons (CFCs) consist of? - ✔✔-Chlorine, fluorine, carbon CFCs are chemically very stable because they contain no? - ✔✔-Hydrogen CFCs are damaging to what layer of the ozone layer? - ✔✔-Stratospheric Of the three common types of refrigerants this one has the highest ozone depletion potential (ODP) - ✔✔-CFCs These test methods are assumed by the EPA as the most effective methods for locating the general area of small leaks - ✔✔-Electronic and ultrasonic After recovery of a system, if the pressure rises above ambient pressure then what is most likely happening? - ✔✔-Trapped refrigerant is probably boiling off In cases where the refrigerant cannot be reclaimed due to contamination with other refrigerants, what must be done to the refrigerant? - ✔✔-Must be destroyed by incineration at an approved facility Where should the system vacuum gauge be connected? - ✔✔-As close as possible to the system being evacuated Import of CFCs will be banned after December 31, what year? - ✔✔-1995 A second category of refrigerant is currently available which is hydrochlorofluorocarbons (HCFCs). Although they contain chlorine, which is damaging to the ozone layer, they also contain this which makes them chemically less stable once they enter the atmosphere. - ✔✔-Hydrogen Under EPA's regulations, reclaimed refrigerant must meet what standards for purity before it can be resold? - ✔✔-ARI-700 What type of recovery devices are so named because they depend on components of the system; that is, they capture refrigerant with the assistance of components in the air conditioning or refrigeration equipment as they are emptying. - ✔✔-System dependent All devices used for refrigerant recovery must meet what standards? - ✔✔-EPA What is one HCFC? - ✔✔-R-22 Refrigerants that contain no chlorine at all are called? - ✔✔-HFCs CH2FCF3 refrigerant is a? - ✔✔-HFC Ozone in the stratosphere consist of molecules containing how many oxygen atoms? - ✔✔-3 What's in refrigerants causes ozone destruction? - ✔✔-Chlorine CFCs are able to reach the stratosphere because? - ✔✔-They are chemically very stable The lower case letter following the refrigerant number, as in 134a for example, is the? - ✔✔-Form of the isomer What refrigerants are toxic? - ✔✔-Group 2 What group of refrigerants are nonflammable mixtures of group 1 & 3 refrigerants, which are nonflammable as formulated but who's composition can become flammable do to fractionation under some leakage situations - ✔✔-Group 4 What group of refrigerants are flammable but not toxic? - ✔✔-Group 3 What group of refrigerants do not show flame propagation? - ✔✔-Group 1 R-134a refrigerant tanks are what color? - ✔✔-Light Blue Disposable cylinders are manufactured to specifications established by? - ✔✔-DOT Every refrigerant cylinder is equipped with what device that will automatically vent pressure from the cylinder before it reaches the rupture point? - ✔✔-Safety (pressure) relief valve Refillable cylinders are regulated in their design, fabrication & tested by who for use in the transportation of refrigerants? - ✔✔-DOT Capturing and ultimately eliminating the use of chlorofluorocarbons is being done in the United States to stop damage to what layer of the ozone? - ✔✔-Stratospheric State and local government's may establish laws that contain what kind of regulations than Clean Air Act/EPA regulations? - ✔✔-Stricter What does the clean air act state? - ✔✔-Calls for the phase-out of CFC/HCFC production also prohibits CFC/HCFC venting as of July 1, 1992 and requires the EPA to set standards for equipment and technicians Before you dispose of any appliance containing what refrigerant, you must recover the refrigerant - ✔✔- CFC, HFC, HCFC CFCs can no longer be manufactured or imported into the United States after what year? - ✔✔- December 31, 1995 Recovery cylinders are painted what color in the shoulder area and 12 inches down the side? - ✔✔- Yellow Refrigerant cylinders must be retested at what intervals? - ✔✔-Five years Chemically, oxygen is O2 & ozone is? - ✔✔-O [Show More]

Last updated: 1 year ago

Preview 1 out of 10 pages

Add to cart

Instant download

document-preview

Buy this document to get the full access instantly

Instant Download Access after purchase

Add to cart

Instant download

Reviews( 0 )

$8.00

Add to cart

Instant download

Can't find what you want? Try our AI powered Search

OR

REQUEST DOCUMENT
79
0

Document information


Connected school, study & course


About the document


Uploaded On

Mar 20, 2023

Number of pages

10

Written in

Seller


seller-icon
Topmark

Member since 1 year

66 Documents Sold


Additional information

This document has been written for:

Uploaded

Mar 20, 2023

Downloads

 0

Views

 79

Document Keyword Tags

What is Browsegrades

In Browsegrades, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Browsegrades · High quality services·