Health Care > QUESTIONS & ANSWERS > Sterile Processing Board Exam Questions and Answers Already Passed (All)

Sterile Processing Board Exam Questions and Answers Already Passed

Document Content and Description Below

Sterile Processing Board Exam Questions and Answers Already Passed A broken glass suction bottle is returned to decontamination. Which of the following should the technician do- ✔✔place it in t... he appropriate rigid container Material Safety Data Sheets provide health and safety hazard and risk information on which of the following- ✔✔chemical Which of the following is an ethical responsibility of an individual working in the central processing department- ✔✔maintaining patient confidentiality Which of the following generally describes the correct sequence for the traffic work flow in areas for which medical devices are processed- ✔✔decontamination, assembly, packaging, sterilization, sterile storage A spiral shaped line in a picture in a picture- ✔✔spirochete Which of the following agencies would approve the disinfectants used on floors and walls in the sterile processing and the distribution department- ✔✔environmental protection agency Clean to Dirty is an SPD term used to describe- ✔✔traffic patterns Loose fitting clothing and jewelry should not be worn in SPD because it can- ✔✔get caught in moving equipment Rod-Shaped bacteria is called- ✔✔bacilli A liver biopsy would be performed to check for which disease- ✔✔hepatitis C virusA patient contracts an infection from an improperly sterilized instrument. This is an example of what- ✔✔nosocomial infection A staff member brings several contaminated trays to the SPD on a cart and requests that replacement trays be put on the same cart. The technician should- ✔✔clean and dry the transport cart and send it to distribution for the trays Healthcare workers are most likely to be infected by which of the following agents- ✔✔hepatitis B Which of the following best describes the manual cleaning process of surgical instruments- ✔✔scrubbing the instrument in a detergent solution A technician notices a maintenance person working in decon did not remove their PPE after leaving the area. The technician should- ✔✔ask the maintenance person to remove PPE when leaving the area While delivering Sterile supplies to multiple units, the sterile technician is asked to take an opened used tray to decon. Which of the following is the best procedure to use- ✔✔return for the used trays with the appropriate cart after completing all deliveries The PH of detergent solution that has been demonstrated to be the safest for cleaning surgical instruments is- ✔✔neutral Which of the following solutions is generally considered most appropriate for high-level disinfection of instruments- ✔✔2% activated gluteraldhyde After manually cleaning contaminated surgical instruments with a disinfectant solution the next step is- ✔✔rinsingThe first step in removing blood contamination from the channels of an instruments is to soak it in- ✔✔enzymatic detergent When cleaning an IV pump it is important to use germicide on the pump surface in order to- ✔✔reduce the bioburden present on the equipment If it is not possible to wash contaminated instruments immediately after use, they should be kept moist by- ✔✔spraying with an enzymatic foam, covering them with a towel moistened with water, and placing them in a plastic bag A tray of instruments has been brought to the decon area in a saline solution. What should be done- ✔✔rinse them with water then clean in usual manner An acceptable method of decontaminating an item that has been used on a patient is to- ✔✔clean with a detergent solution and then use an appropriate disinfection agent Transmission of pathogenic organisms from used surgical instruments can best be minimized by- ✔✔wearing appropriate PPE When using the sequential wrapping method- ✔✔apply one wrapper followed by a second one Surgical grade instruments last longer because they have- ✔✔passivation layer Instruments for an emergency ruptured aortic aneurysm- ✔✔major vascular instruments Disadvantage of using a rigid sterile container system- ✔✔they must be disassembled, processed, reassembled, and checked before each useContainerized packaging systems are used to protect- ✔✔flexible fiberoptic endoscopes Simultaneous wrapping is what- ✔✔a single non-woven, double-ply, bonded at the edges Clamps used for hemostasis are also designed to- ✔✔minimize tissue damage Instrument tray for a laparotomy p [Show More]

Last updated: 1 year ago

Preview 1 out of 8 pages

Add to cart

Instant download

document-preview

Buy this document to get the full access instantly

Instant Download Access after purchase

Add to cart

Instant download

Also available in bundle (1)

C.S. Certification Exam, SPD Test, Sterile Processing Bundle. Complete Questions with accurate answers,

C.S. Certification Exam, SPD Test, Sterile Processing Bundle. Complete Questions with accurate answers, All ypu need to score A

By bundleHub Solution guider 1 year ago

$45.5

32  

Reviews( 0 )

$10.00

Add to cart

Instant download

Can't find what you want? Try our AI powered Search

OR

REQUEST DOCUMENT
97
0

Document information


Connected school, study & course


About the document


Uploaded On

Sep 27, 2022

Number of pages

8

Written in

Seller


seller-icon
bundleHub Solution guider

Member since 2 years

313 Documents Sold


Additional information

This document has been written for:

Uploaded

Sep 27, 2022

Downloads

 0

Views

 97

Document Keyword Tags

More From bundleHub Solution guider

View all bundleHub Solution guider's documents »

$10.00
What is Browsegrades

In Browsegrades, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Browsegrades · High quality services·